fieldcommunicator

MTL4516 MTL4516C MTL5516C Switch Proximity Detector Interfac

description:MTL4516 MTL4516C MTL5516C Switch Proximity Detector Interface ...
BASIC INFO
MTL4516 MTL4516C MTL5516C Switch Proximity Detector Interface



 
 
The MTL5516C enables two safe-area loads to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the line-fault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for each channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.
 
Shipping weight: 1 kg
 
 
 
SPECIFICATION of 
MTL4516 MTL4516C MTL5516C Switch Proximity Detector Interface
 
Number of channels
Two
 
Location of switches
Zone 0, IIC, T6 hazardous area
Div. 1, Group A hazardous location
 
Location of proximity detector
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A hazardous location
 
Hazardous-area inputs
Inputs conforming to BS EN60947–5–6:2001 standards for
proximity detectors (NAMUR)
 


MTL4516 MTL4516C MTL5516C Switch Proximity Detector Interface

Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
 
Input/output characteristics
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal



MTL4516 MTL4516C MTL5516C Switch Proximity Detector Interface
 
Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. Line faults are
indicated by an LED for each channel. The channel output relay is
de-energised if an input line fault is detected.
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input
500Ω to 1kΩ in series with switch
20kΩ to 25kΩ in parallel with switch
 



MTL4516 MTL4516C MTL5516C Switch Proximity Detector Interface

Safe-area output
Two single-pole relays with changeover contacts
Note: reactive loads must be adequately suppressed
 
 
Maximum current consumption
35mA at 24V
 
Power dissipation within unit
0.84W at 24V



We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
 
We mainly supply YOKOGAWA,WEIDMULLER, ABB, MOELLER, SCHNEIDER ElECTIC,FUJI,OMRON,HONEYWELL,SIEMENS,FLUKE,PEPPERL+FUCHS,HIMA,Endress+ Hauser etc.
 
Why choose us?
 
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
 
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
  
3. SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 
Packaging: 
Imported with original packaging or standard export packing.Customize design is acceptable.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)
 
Previous: Next:MTL4546Y Safety Barrier Isolating Driver 1ch 4 to 20mA for S
 Footer begin -->